In situ adjustment Plate

Les Vis Ostéosynthèses Ortrautek - Global D sont dédiées à la chirurgie Orthognathique, traumatologique et à la petite reconstruction.

In situ mandibular adjustment plates

During intermaxillary release, the on-site adjustment plate allows direct adjustment of the occlusal plane if necessary, without dismantling the osteosynthesis material. It thus prevents unpredictable lateral, vertical, or anteroposterior movements of the mandible.

The advantages of the Global D range of field-adjustable plates

  • A wide range of models of plates that can be bent or adjusted on site,
  • Single-vector or dual-vector adjustment depending on the plate,
  • Different grades of titanium to meet all clinical and surgical indications and patient-specific requirements.

Natural Fit Plate

Plaque Natural Fit de la gamme Ortrautek

The Natural Fit anatomical plate has been designed with an initial 3D shape that adapts perfectly to the shape of the external cortical bones of most types of mandible while limiting stress on the TMJ (compression or torque).

  • Alignment of the 4 holes in a circular arc to:
    • Cause clockwise rotation of the condyle during osteosynthesis, thereby avoiding posterior compression of the TMJ
    • Follow the shape of the basilar edge, thereby limiting the problem of basilar notch during significant advances
  • Spiroidal shape along its major axis, avoiding stress on the TMJ
  • Concave profile for good adaptation to the outer cortex
  • Curved proximal and distal ends to avoid stress on the TMJs

 

The Natural Fit adjustable plate allows:

  • On-site adjustment of the osteosynthesis without having to dismantle all the equipment
  • Optimal condylar positioning without compression during osteosynthesis

Dr. CRESSEAUX PLATE – ± 1 mm

Plaque à Réglage sur site - Gamme Ortrautek

Fine adjustment of osteosynthesis

  • Deformable hexagonal area allowing targeted intraoperative adjustment
  • Correction capacity limited to ± 1 mm
  • Indicated for small-amplitude occlusal adjustments

Dr. DUGUET'S PLATE – ± 2 mm

Single-vector anterior-posterior correction

  • Deformable diamond on site
  • Single-vector adjustment in the anterior-posterior axis
  • Adjustment range extended to ± 2 mm

DIAMOND-SHAPED PLATES – 0.8 mm

Three-dimensional intraoperative adjustment

  • Controlled deformation of the central diamond
  • Combined horizontal, vertical, and bending adjustments
  • Adaptation to complex anatomical variations

SLIDE PLATES – 1 mm

Intraoperative adjustment of mandibular occlusion

  • Fine adjustment of occlusion thanks to the central oblong hole
  • Intraoperative anterior-posterior monovectorial adjustment
  • Controlled sliding allowing gradual adaptation of the mandibular position
  • Maintenance of mechanical stability after locking
  • Indicated for fine occlusal corrections and secondary adjustments

DR. BALOGH PLATE ON BRIDGE – 1 mm

Intraoperative adjustment of occlusion

  • Anatomical shape adapted to the external oblique line
  • Transverse flexibility allowing controlled condylar adaptation
  • Intraoperative occlusal adjustment with controlled correction vector

SHORT OSTEOTOMY LATES – 1 mm

Intraoperative adjustment of occlusion

  • 1 mm thickness providing rigidity adapted to mandibular stresses
  • Horizontal slide allowing intraoperative adjustment up to 5 mm
  • 6 fixation holes ensuring stable osteosynthesis